Thermo connect
Author: s | 2025-04-23
Connect your instrument to your Thermo Fisher Connect account to view and manage your instruments and data remotely. For more information on Thermo Fisher Connect and managing your connected instruments, see the Help guide in the Thermo Fisher Connect application.
Connect an Instrument to a Thermo Fisher Connect
Data from all your stores to provide a single source of truth.Collect and store data according to Findable, Accessible, Interoperable, Reusable (FAIR) data principles and enable AI/MLData integrity features address data and application access, from creation through to retentionImport legacy data to enable insights from historical and larger data setsSecure, centralized repository enables advanced analytics Vendor agnostic instrument connection The Connect Platform can connect to many types of instruments and equipment. Cloud-enabled instruments from Thermo Fisher ScientificEnter your Connect Platform account credentials directly on the instrument screen to connect when connected via Ethernet or Wi-Fi, and the instrument shows up in your Connect Platform instrument dashboard.Connect instruments from other vendorsDownload Thermo Fisher Connect Transfer software for Windows to automatically upload your data files from these instruments into your Connect Platform storage.Equipment without connectivity Attach one of our connectivity devices such as the Device Link Connect or a Thermo Scientific Smart Vue Pro Remote Monitoring Solution system to compatible freezers, refrigerators and incubators, to transform them into connected equipment. Comprehensive data security Thermo Fisher Scientific has implemented various safeguards and procedures designed to help protect the Connect Platform, Individual and Team editions against intrusion and data compromise. The Connect Platform was designed and developed in collaboration with our Corporate Cybersecurity Program, which provides technical, administrative, and physical safeguards for detecting vulnerabilities and addressing potential threats.Please view our security quick reference quide for more information on the security controls and practices implemented within the Connect Platform. Connect your instrument to your Thermo Fisher Connect account to view and manage your instruments and data remotely. For more information on Thermo Fisher Connect and managing your connected instruments, see the Help guide in the Thermo Fisher Connect application. Connecting the USB-enabled Wi-Fi Card into ™ the SimpliAmp Thermal Cycler. To set up the wireless connection: wireless connection 1. Page 44: Use Instrument Without Signing In Appendix A Install and connect to a network Set up the system • WPA Enterprise • WPA2 Enterprise Note: The above options are available only if you selected Join Other Network in step 3. You cannot change the security type if you selected an existing network. 6. Page 45: Sign Out Appendix A Install and connect to a network Set up the system Sign out In the home screen: 1. Touch My Profile. 2. Touch Sign Out. Set up mobile and cloud connectivity Create an account on Thermo Fisher Connect ™ to SimpliAmp 1. Page 46: Link Instrument Profile To Your Thermo Fisher Connect Account Appendix A Install and connect to a network Set up the system 9. Upon successful authentication, the Administrator is linked to Thermo Fisher Connect. Subsequently, any user can log in and proceed to perform linking the instrument to their Thermo Fisher Connect account. Note: The administrator account must be activated first to connect the instrument to the Cloud. Page 47 Appendix A Install and connect to a network Set up the system Set up mobile connectivity on a mobile device Download the "Instrument Connect Mobile Application" on your mobile device. 1. For an iPad or an iPhone , download the application from the iTunes music ™... Page 48: Recommended Instrument Settings Appendix A Install and connect to aComments
Data from all your stores to provide a single source of truth.Collect and store data according to Findable, Accessible, Interoperable, Reusable (FAIR) data principles and enable AI/MLData integrity features address data and application access, from creation through to retentionImport legacy data to enable insights from historical and larger data setsSecure, centralized repository enables advanced analytics Vendor agnostic instrument connection The Connect Platform can connect to many types of instruments and equipment. Cloud-enabled instruments from Thermo Fisher ScientificEnter your Connect Platform account credentials directly on the instrument screen to connect when connected via Ethernet or Wi-Fi, and the instrument shows up in your Connect Platform instrument dashboard.Connect instruments from other vendorsDownload Thermo Fisher Connect Transfer software for Windows to automatically upload your data files from these instruments into your Connect Platform storage.Equipment without connectivity Attach one of our connectivity devices such as the Device Link Connect or a Thermo Scientific Smart Vue Pro Remote Monitoring Solution system to compatible freezers, refrigerators and incubators, to transform them into connected equipment. Comprehensive data security Thermo Fisher Scientific has implemented various safeguards and procedures designed to help protect the Connect Platform, Individual and Team editions against intrusion and data compromise. The Connect Platform was designed and developed in collaboration with our Corporate Cybersecurity Program, which provides technical, administrative, and physical safeguards for detecting vulnerabilities and addressing potential threats.Please view our security quick reference quide for more information on the security controls and practices implemented within the Connect Platform.
2025-03-25Connecting the USB-enabled Wi-Fi Card into ™ the SimpliAmp Thermal Cycler. To set up the wireless connection: wireless connection 1. Page 44: Use Instrument Without Signing In Appendix A Install and connect to a network Set up the system • WPA Enterprise • WPA2 Enterprise Note: The above options are available only if you selected Join Other Network in step 3. You cannot change the security type if you selected an existing network. 6. Page 45: Sign Out Appendix A Install and connect to a network Set up the system Sign out In the home screen: 1. Touch My Profile. 2. Touch Sign Out. Set up mobile and cloud connectivity Create an account on Thermo Fisher Connect ™ to SimpliAmp 1. Page 46: Link Instrument Profile To Your Thermo Fisher Connect Account Appendix A Install and connect to a network Set up the system 9. Upon successful authentication, the Administrator is linked to Thermo Fisher Connect. Subsequently, any user can log in and proceed to perform linking the instrument to their Thermo Fisher Connect account. Note: The administrator account must be activated first to connect the instrument to the Cloud. Page 47 Appendix A Install and connect to a network Set up the system Set up mobile connectivity on a mobile device Download the "Instrument Connect Mobile Application" on your mobile device. 1. For an iPad or an iPhone , download the application from the iTunes music ™... Page 48: Recommended Instrument Settings Appendix A Install and connect to a
2025-03-24Series... Page 25: Clean Water-Cooled Condenser 8. Add and circulate a passivating liquid for corrosion inhibition of plate surfaces. 9. Drain this liquid. 10. Rinse with fresh water and drain. 11. Reconnect the water supply and fill the unit. 12. Return to service. TSE Series Thermo Scientific... Page 26: Defrost Chamber The unit is designed with a “vacuum relief port” that allows the pressure to be equalized. Thermo Scientific TSE Series... Page 27 Warning Failure to maintain the vacuum relief port may result in excessive ice build up inside the tube, clogging the port, and inability to open the door. The vacuum relief port may need to be cleaned more often with frequent door openings and high humidity environments. TSE Series Thermo Scientific... Page 28: Prepare Unit For Storage Note If the unit has been in service, turn it off and disconnect the power cord connector before proceeding with any maintenance. Battery power switch Thermocouple interconnect jack Battery mounting bracket Freezer battery and optional BUS battery Figure 4-6. Battery Power Switch Thermo Scientific TSE Series... Page 29: Preventive Maintenance Locate the freezer away from drafts or heating/cooling vents • Keep the number of door openings to a minimum • Minimize the length of time door is open • Make sure door latches securely after opening TSE Series Thermo Scientific... Page 30: Factory Installed Options 5. Remove the two Phillips head screws securing the metal bracket on the vent stack assembly. 6. Install the vent stack through the opening and secure it to the top of the freezer, using screws. Thermo Scientific TSE Series... Page 31 Section 5 Factory Installed Options Install Vent Stack, Solenoid and Injection (continued) Figure 5-1. Injection Assembly Figure 5-2. Vent Stack Assembly TSE Series Thermo Scientific... Page 32: Install Temperature Probe 3. Tap #8-32 the two pre-punched holes located on the interior left wall of the freezer. Mount the bracket. Figure 5-4 shows the Back-Up probe mounted on the interior left side wall of the freezer. Figure 5-4. Mounted probe clip Thermo Scientific TSE Series... Page 33: Connect Probe/Solenoid Harness (no injection occurs). This light stays
2025-04-20Compatible with smart speakers ThermoConnect supports voice commands via smart speakers such as Alexa Skill which can be used to control the Webasto parking heater. If a Cronus control unit is installed to control the Webasto parking heater, the device can also be operated via Bluetooth without an additional control unit in the immediate vicinity.\r\n"}}"> Bluetooth connectivity If a Cronus control unit is installed to control the Webasto parking heater, the device can also be operated via Bluetooth without an additional control unit in the immediate vicinity. Product details Product specifications\r\n \r\n\r\nNominal voltage: 12 V, 24 V\r\n2G and 4G\r\nApp for Android and iOS\r\nAlexa skill available\r\nSelectable heating times between one minute and 24 hours\r\nCompatible with Webasto air heaters and water heaters\r\nAvailable in: Andorra, Belgium, Bulgaria, Denmark, Germany, Finland, France, Greece, Greenland, Great Britain, Ireland, Iceland, Italy, Liechtenstein, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Sweden, Spain, Slovakia, Slovenia, Czech Republic, Cyprus\r\n\r\n"}}" id="text-95f1546398"> Product specificationsNominal voltage: 12 V, 24 V2G and 4GApp for Android and iOSAlexa skill availableSelectable heating times between one minute and 24 hoursCompatible with Webasto air heaters and water heatersAvailable in: Andorra, Belgium, Bulgaria, Denmark, Germany, Finland, France, Greece, Greenland, Great Britain, Ireland, Iceland, Italy, Liechtenstein, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Sweden, Spain, Slovakia, Slovenia, Czech Republic, Cyprus Downloads Thermo Connect for iOS\r\nDownload the ThermoConnect app for your iOS devices HERE.\r\n"}}" id="text-8bc4cbd0ac"> Thermo Connect for iOSDownload the ThermoConnect app for your iOS devices HERE.Thermo Connect for Android\r\nDownload the ThermoConnect app for Andoid HERE.\r\n"}}" id="text-8e1449ab3c"> Thermo Connect for AndroidDownload the ThermoConnect app for Andoid HERE.
2025-04-18Calibration probe additional Sensor sealant Optional recorder / CAUTION: This is critical seal. datalogger probe Seal must be maintained. Control RTD/Redundant Type T Thermocouple probe Figure 1-3. Chamber Probe(s) TSE Series Thermo Scientific Thermo Scientific... Page 10 Battery mounting bracket Freezer battery and optional BUS battery Figure 1-5. Battery(s) location and switch • Battery mounting bracket(s) • Battery power switch (freezer and BUS) • Freezer battery • Optional BUS battery • Freezer filter location Thermo Scientific TSE Series... Page 11: Control Panel Keys, Displays, Indicators Silence - Silences the audible alarm. See Section 4 for alarm ringback times. • Alarm Panel - indicates the current alarm condition. • Up and Down Arrows - Increases or decreases values, toggles between choices. • Enter - Stores the value into memory TSE Series Thermo Scientific... Page 12: Operation Of The Keypad Section 1 Installation and Start-Up Operation of the The TSE Series freezer has five basic modes which allow freezer setup and operation. Press the Mode key to scroll through the mode selections. Keypad Up Arrow: Increases or toggles the parameter value. Page 13: Install Wall Bumpers IMPORTANT USER INFORMATION aution! Stored product should be protected by a redundant 24 hour/day monitoring system with alarm capability. An interconnect jack and thermocouple are installed for centralized monitoring, should on-board system fail. Figure 1-8. Remote Alarm Contacts TSE Series Thermo Scientific... Page 14: Connect Unit To Electrical Power 36 hours to charge at initial start-up. A “Low Battery” alarm may occur until the batteries are fully charged. Should a power failure occur during the initial start-up period, the electronics will have limited operation. Thermo Scientific TSE Series... Page 15: Set Operating Temperature 10° from set point. Set Operating TSE Series freezers have an operating temperature range of -50°C to 86°C, depending on ambient temperature. The freezer is shipped from the Temperature factory with a temperature set point of -80°C. To change the operating temperature set point: 1. Page 16: Set Low Temperature Alarm 4. Press the Mode key until the Run indicator lights for Run mode If no control keys are pressed, the freezer will
2025-04-13